The Chimney Sweep Woodstoves, Gas Stoves, Fireplaces, Cookstoves and Barbecues
The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop

Gas Service Checklist

CUSTOMER NAME __________________    STOVE MODEL ________________
ADDRESS       __________________    SERIAL NUMBER ______________
DATE          __________________    DATE CODE __________________
1:  LINE PRESSURE    ARROW+   AVALON+  NOVUS+    HEARTH-   WATER-    
    LOW - HIGH       DOVRE    AVANTI   MENDOTA   STONE     FORD
    NG __________    4.5-7    5.5-7    4.5-10.5  4.5-10.5  4.5-11
    LP __________    11-14  11.5-13.5  10.5-13   11-13.5   11-13
2:  MANIFOLD PRES.   ARROW+   AVALON+  NOVUS+    HEARTH-   WATER-    
    LOW - HIGH       DOVRE    AVANTI   MENDOTA   STONE     FORD
    NG __________   1.7-3.5   1.0-3.5  1.5-3.5   1.5-3.5  1.5-3.5
    LP __________    5.4-11   2.7-11   3-10.5    2.5-10   2.5-10
3:  DETERMINE WIRING PROPERLY CONNECTED TO GAS VALVE (CHECK):
    THERMOPILE IS CONNECTED TO SCREWS #1 & #2 (TH/TP & TP) _____
    THERMOSTAT IS CONNECTED TO SCREWS #1 & #3 (TH/TP & TH) _____
    ALL FITTINGS CLEAN AND TIGHT _______
4:  THERMOSTAT WIRE IS PROPER SIZE _____ WIRE SIZE    MAX. LENGTH
                                           14 GA.       100 FT.      
                                           16 GA.        64 FT.
                                           18 GA.        40 FT.
                                           20 GA.        25 FT.
                                           22 GA.        16 FT.
5:  MILLIVOLT SYSTEM TESTS (FILL IN READING):     AVALON/   ALL
                                                  AVANTI   OTHERS
SYSTEM: BURNERS LIT, 2(TP) & 3(TH)  _______        >125     >100
OUTPUT: PILOT ONLY, 1(TH/TP) & 2(TP) ______        >350     >325
RESISTANCE: BURNERS LIT, 1(TH/TP) & 3(TH) _____     <80     SAME
EPU CURRENT TEST: PILOT LIT, 2(TP) & EPU _____     >125     SAME

6:  SPILL SWITCH TEST:
    SET GUAGE TO TONE; DISCONNECT TWO WIRES FROM SPILL
    SWITCH, TOUCH ONE PROBE TO EACH WIRE. TONE INDICATES
    WIRING TO SPILL SWITCH IS OK. ______ (CHECK IF OK)

7:  EXHAUST CONNECTOR AND CHIMNEY FLUE ARE CLEAR _________
8: PILOT AND BURNER ORIFICES ARE CLEAR ________
9: BURNER OPENINGS ARE CLEAR________
10: AIR SHUTTER IS PROPERLY ADJUSTED__________
11: NO LEAKS DETECTED IN APPLIANCE, SUPPLY LINE OR EXHAUST SYSTEM ________
       

The Chimney Sweep, Inc.
913 Harris Avenue
Bellingham, WA 98225-7032
1(888)-354-6722 toll-free in U.S. & Canada
1(360)-676-9080 FAX
http://www.chimneysweeponline.com

To send us E-Mail, Click Standard E-Mail Window or contact us (our reply form)
Copyright © 1996 - 2009 The Chimney Sweep, Inc.