The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
STOVE MODEL: HEARTHSTONE TRIBUTE DIRECT VENT GAS STOVE STOVE DIMENSIONS: 23 7/8" WIDE X 18" DEEP X 24 1/8" TALL
EXHAUST PIPE USED: 4" ID X 6-5/8" OD COAXIAL PIPE
NO HEARTH (FLOOR PROTECTION REQUIRED ON ANY FLOOR SURFACE
VENTING OPTIONS: HORIZONTAL VENT: STRAIGHT BACK (NO VISIBLE PIPE) TO 13-1/2" SQUARE x 6 3/4"D HORIZONTAL CAP THROUGH FIREPLACE: ADAPT TO 3"/3" CO-LINEAR FLEX PIPE THROUGH FIREBOX TO TOP SEALER PLATE. VERTICAL VENT: STRAIGHT UP (MAXIMUM 30 FT.) THROUGH ROOF FLASHING TO 6 5/8" ROUND CAP
FLAT BACKWALL CORNER VERTICAL VENT HORIZONTAL VENT
FLAT WALL INSTALLATIONS | CORNER INSTALLATIONS |
A: STOVE TO BACKWALL IF VERTICAL VENTED.......... 11-5/8" IF HORIZONTAL VENTED............. 2" | G: STOVE CORNERS TO CORNER WALLS...... 2" |
B: STOVE TO SIDEWALL................ 2" | H: CENTERLINE OF VERTICAL PIPE TO CORNER WALLS................ 6-1/4" |
C: CENTERLINE OF VERTICAL PIPE TO BACKWALL................. 5-3/16" | I: CORNER TO CENTERLINE OF PIPE... 8-3/4" TO FRONT OF WINDOW............ 32-3/4" |
D: CENTERLINE OF PIPE TO SIDEWALL.. 14" | M: FLOOR TO CENTERLINE OF EXHAUST PIPE IF HORIZONTAL VENTED.......... 16-3/4" |
E: BACKWALL TO FRONT OF DOOR: IF VERTICAL VENTED.......... 31-5/8" IF HORIZONTAL VENTED............ 20" | N: FLOOR TO TOP OF HORIZONTAL VENT CAP IF HORIZONTAL VENTED.......... 23-1/2" |
NOTE: HORIZONTAL VENT PIPE MUST RISE 1/4"/FT (NATURAL GAS), 1/2"/FT (LP GAS)
COMBUSTIBLE ALCOVE DIMENSIONS: MINIMUM 26-1/4"W X 33-1/8"T, MAXIMUM 18-1/2"D
TOP OF STOVE TO OVERHANGING COMBUSTIBLES: 9"
| When the Tribute DV is installed inside or in front of an existing fireplace, use a co-linear intake/exhaust system.If the Tribute DV is to stand inside the fireplace as shown in Diagram A, a co-linear converter is attached directly to the rear exhaust collar: if the Tribute DV is to stand outside the fireplace on the hearth as shown in Diagram B, a length of co-axial pipe is used between the converter and the exhaust collar. The converter is then connected to a similar box at the flue top by two lengths of 3" aluminum flex, one for intake and one for exhaust. A coaxial rain cap completes the installation. With this system, combustion air is contained within the intake flex so it can't enter the room through the fireplace opening.Minimum Fireplace Opening Height:
|
|